Home » Industry News » Application » How to Test an IGBT Using A Multimeter

Testing an Insulated Gate Bipolar Transistor (IGBT) using a multimeter is an effective way to check its health and functionality. This process involves measuring the diode-like characteristics, resistance, or conductivity between its pins to identify potential shorts, open circuits, or other issues. Below is a step-by-step guide on how to test an IGBT using a multimeter, along with some important considerations.

Preparation Before Testing

1. Power Off and Discharge the IGBT

Before testing, ensure the IGBT is completely powered off to avoid the risk of electrical shock or damage to the device. Also, discharge the gate by shorting the gate (G) and emitter (E) pins for a few seconds. This step releases any residual charge from the gate capacitance.

2. Understand the Pinout

Refer to the IGBT’s datasheet to identify the pins correctly. Typically, the pins are arranged as follows:

  • G – Gate
  • C – Collector
  • E – Emitter

If the datasheet is unavailable, visually inspect the IGBT. The pins connected to the heat sink are usually the Collector or Emitter.

Read More: What Is an IGBT?

3. Set the Multimeter

IGBT tester

Select the diode test mode or set the multimeter to a high resistance range (typically 20kΩ or higher). The diode mode is particularly useful for testing the IGBT’s diode-like properties.

Testing Steps

1. Test the Collector to Emitter Diode Characteristics

Steps:

  • Connect the red (positive) probe to the Emitter (E) pin.
  • Connect the black (negative) probe to the Collector (C) pin.

Expected Result: The multimeter should show a forward voltage drop of approximately 0.4V to 1.5V, depending on the IGBT model.

  • Reverse the probes: Connect the red probe to Collector (C) and the black probe to Emitter (E).

Expected Result: The multimeter should display infinity or OL (open loop), indicating no conduction in the reverse direction.

Abnormal Signs:

  • If both readings show conduction (i.e., a low resistance in both directions), the IGBT may have a shorted diode inside.
  • If both readings show infinite resistance, the IGBT could be open or the internal diode may have failed.

2. Test the Gate to Emitter Resistance

Steps:

  • Connect the red (positive) probe to the Gate (G) and the black (negative) probe to the Emitter (E).

Expected Result: The resistance should be extremely high (almost infinite).

  • Reverse the probes and repeat the test.

Expected Result: The resistance should remain the same—very high.

Abnormal Signs:

  • If the resistance is significantly lower than expected (e.g., in the range of kΩ or less), the gate insulation may have failed or shorted.

3. Test the Gate to Collector Resistance

Steps:

  • Place the red (positive) probe on the Gate (G) and the black (negative) probe on the Collector (C).

Expected Result: Similar to the previous test, the resistance should be very high (near infinity).

Abnormal Signs:

  • A low resistance reading suggests that there is a short circuit between the gate and collector.

4. Gate Trigger Test (Optional, Dynamic Test)

This test requires temporarily applying a voltage to the gate to simulate activation.

Steps:

  • Using a 9V battery, briefly connect the positive terminal to the Gate (G) and the negative terminal to the Emitter (E).
  • Immediately measure the Collector to Emitter resistance.

Expected Result: When the gate is triggered, the resistance between Collector (C) and Emitter (E) should drop (indicating conduction). Once you disconnect the 9V battery, the resistance should return to a high value, indicating that the IGBT has turned off.

Abnormal Signs:

  • If the IGBT does not trigger or fails to turn off properly, this may indicate a faulty gate oxide layer or other internal damage.

Key Considerations

1. Electrostatic Protection

IGBTs are sensitive to static electricity, especially at the gate. It is recommended to wear an anti-static wrist strap to prevent damaging the device during handling.

2. Multimeter Limitations

Keep in mind that a multimeter can only measure static characteristics, such as resistance and diode-like behavior. It cannot assess the dynamic performance of the IGBT, such as switching speed, voltage withstand, or thermal properties. If you suspect dynamic failure, a specialized tester or test circuit may be required.

3. Reference the Datasheet

The voltage drop, threshold values, and other parameters can vary between IGBT models. Always consult the datasheet for the specific part number you are testing to know the exact expected values.

Common Faults and Their Causes

By following these steps, you can effectively check the health of an IGBT using a multimeter. If the results indicate abnormalities, it’s advisable to replace the component to avoid issues in your circuit.

Read More:

BJT vs MOSFET​
IGBT vs. GTO
IGCT vs. IGBT
IGBT vs Thyristor
How to Test an IGBT Using A Multimeter

What Is an IGBT?

Amazon Today's Deals - Electronics Special Offers
AMAZON ELECTRONICS SPECIAL OFFERS

Today's Electronics Deals & Special Offers

Looking for a better price on your next tech purchase? Explore Amazon electronics deals, special offers and savings across popular tech categories.

EXPLORE TODAY'S DEALS ↗

Explore Electronics Deals

16 CATEGORIES
MORE TECH. MORE SAVINGS.

Ready to Find Your Next Tech Deal?

Browse Amazon's latest electronics offers and discover deals across a wide range of categories.

SHOP ALL ELECTRONICS DEALS ↗

As an Amazon Associate, we earn from qualifying purchases.

Leave a Reply

Your email address will not be published. Required fields are marked *

This site uses cookies to offer you a better browsing experience. By browsing this website, you agree to our use of cookies.